Aerostat® Guardian

• AC Corona Ionization. Eliminates Static from Ungrounded Objects

• Integrated Heater and Task Lights

• 120V, 60 HZ, UL Listed in USA and Canada

• Compatible with Class 100 / Class 5 Cleanrooms

Categories: ,

Specs

Dimension Specification
Input Voltage 120 VAC, 60 Hz: 0.5A (fan low, heater/light off); 2.5A (fan high, heater/light on)
Discharge Time 3 seconds @ 18″ center blower position; fan high no diffusers (1000-100V)
Balance 0±5V @ 18″ from blower fave
Ion Emission AC Ionization
Coverage 2′ x 4′ area
Cleanroom Class Meets ISO 14644-1 Class 5; Fed Standard 209E Class 100
Emitter Points Stainless Steel
Controls Fan speed control knob BLOWER ON; on/off switch HEATER & TASK LIGHT
Indicator Lights Orange IONIZATION STATUS; orange within of/off switches HEATER & TASK LIGHT
Air Volume 150-300 cubic feet per minute (low to high), combined 3-fan output
Heated Air Temp 25F (14C) fan low; 11F (6C) fan high (measured @ 6″ in front of center fan above ambient)
Audible Noise 50 dBA fan low; 60 dBA fan high
Operating Environment Temperature 32-122F (0-50C); humidity 30-70% relative humidity, non-condensing
Ozone 0.02ppm, measured @ 12″ in front of unit
Lamp 13W twin tube, compact fluorescent, 1650 lumen total task light output
Air Filter 30 ppi open cell polyurethane foam (optional)
Mounting Adjustable brackets and S-hooks provided
Enclosure Powder-coated white enamel aluminum
Dimensions 42.75 inches (width) x 4 inches (height) x 6.75 inches (depth) (108.6 x 10.2 x 17.1 cm)
Weight 16 lb (7.3 kg)
Warranty Two year limited warranty